1. REMOVAL (cont)
Disconnect the hydrualic tubing. Hold the elbow with a 1-3/8 inch open end wrench. Remove two nuts
d.
with a 1-1/2 inch open end wrench.
e.
Remove the elbows. Hold elbows with a 1-3/8 inch open end wrench.
f.
Loosen two nut. Use 1-1/2 inch open end wrench.
Remove two elbows. Use 1-3/8 inch open end wrench.
g.
h.
Remove eight bolts and nuts.
i.
Remove reservoir.
GO TO NEXT PAGE