FLOWMETER -- REPAIR
3-100
Disassembly and Assembly
This task covers:
INITIAL SETUP
Equipment
Condition
Condition Description
Para
Personnel Required
Flowmeter removed
68H Aircraft Pneudraulic
Repairman
Materials/Parts
Tools
Elbow and adapter "O" rings
-Part Number MS29512-12
1- in. open end wrench
Flowmeter - Part Number
22092-100
1. DISASSEMBLY
a.
Unscrew adapter from flowmeter and remove rings, using 1- in. open end wrench.
b.
Remove elbow, flowmeter, and remove "O" ring.
2. ASSEMBLY
a.
Install "O" ring on the elbow.
Install elbow in flowmeter, and tighten jam nut.
b.
c.
Install "O" ring on adapter.
Install adapter in flowmeter and tighten.
d.
END OF TASK