THREE-WAY FLOW CONTROL VALVE -- REPAIR -- Continued
3-88
2. ASSEMBLY
a.
Install teflon seal on handle post.
b.
Install "O" ring on handle post.
c.
Insert the post handle assembly into the valve body and up through the handle opening.
d.
Insert the ball spindle into the valve body, aligning the slot with the handle.
Assemble the positioning washer in the noted position. And hold in place with washer and bolt.
e.
f.
Install two "O" rings on connection adapters.
Install two seals and backup ring assemblies.
g.
h.
Install two adapters and tighten.
END OF TASK