MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
HYDRAULIC SYSTEM D5-D HYDRAULIC TEST STAND
1. VOLUME LOSS IN PLUMBING CIRCUIT.
Step 1.
Inspect high pressure pump for leaks.
Step 2.
Inspect for clogged high pressure filter.
Step 3. Inspect compensator control for leaks.
Replace (Para. 3-116) or Repair (Para. 4-15, AVIM).
2. COMPENSATOR FAILS TO OPERATE.
Step 1.
Inspect compensator control for leaks.
Repair (Para. 3-80, AVIM).