Section IV. TROUBLESHOOTING - Continued
3-8
TROUBLESHOOTING CHART - Continued
3-8
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM D5-D HYDRAULIC TEST STAND (cont)
2, SWITCH FAILS TO OPERATE.
Step 1.
inspect for loose wire.
Secure loose wire
Step 2.
Inspect for continuity.
Step 3.
inspect for damaged switch.
3. HIGH PRESSURE FILTER CLOGGED LIGHT FAILS TO LIGHT UP.
Step 1.
Inspect for burned-out bulb.
Replace bulb.
Step 2.
Inspect circuit for continuity.
Replace switch. (Para. 3-56).
Inspect high pressure switch for
Step 3.
damage.
3-28