The batteries (2 each) furnished with the test stand are "dry" type
batteries and have to be activated by the adding of electrolyte (acid)
battery fluid which is shipped with the test stand. This fluid is in
the container secured to the protective screen and resting on the
cover of the battery compartment.
Remove from the container the two individual cartons of electrolyte (acid) battery fluid. Discard the container
a.
and place the cartons (2 each) of electrolyte (acid) battery fluid in a safe place until ready for use.
Remove the four screws securing the battery cover on the battery compartment.
b.
Remove the cover, exposing two batteries.
c.
Remove the vent caps from the batteries.
d.
e.
Each vent opening is sealed with a removable plastic seal.
Remove and discard the plastic seals, a total of 12 seals.
f.
To fill the battery, position one of the electrolyte (acid) battery fluid containers close by the battery to
g.
be filled. The electrolyte container shall be 2 or 3 inches higher than the battery being filled.
h.
Using the thumb, push in the perforated tab at the black dot, pull out the large flap. Reach in
through the opening and pull out the white dispensing hose.