4920-00-176-9236 ">
|
|
TM 55-4920-424-13&P
b. Disconnect APU fuel lines from fuel manifold and from start fuel nozzle.
c. Connect suitable drain lines to disconnected lines, and place open ends of drain lines into a waste fuel container
(one-quart minimum capacity).
d. Connect Battery.
e. Push in MAIN POWER circuit breaker. (See figure E-3).
f. Move START RUN-OFF switch to RUN.
g. Move LITES TEST/ESU RESET switch to ESU RESET three times. Move FUEL BOOST PUMP switch to ON,
Let run approximately 30 seconds, and turn OFF.
h. Move START-RUN-OFF switch from RUN to START, and motor APU until air-free fu el flows from the drain lines;
then, move START-RUN-OFF switch to OFF.
i. Pull MAIN POWER circuit breaker.
j. Disconnect Battery.
k. Disconnect drain lines, and connect APU fuel lines to fuel solenoid valve; or to fuel manifold and start fuel nozzle.
I. Reconnect harness connector to APU ignition exciter.
3-9.
ADJUSTMENT.
3-10. Adjustment procedures are contained in the engine manual for your type APU, refer to the appropriate Technical
Manual.
3-11. OPERATION OF THE APU.
WARNING
Operation of this equipment presents a noise hazard to personnel in the area. The
noise level exceeds the allowable limits for unprotected personnel; wear ear muffs
or earplugs which were fitted by a trained professional.
3-12. Starting APU without APU Tester Box (P/N 161226-200) installed.
a. Place Instrument panel switches in the following positions:
(1) START-RUN-OFF switch to OFF.
(2) FUEL BOOST PUMP switch to OFF.
Change 2 E-19
|