TM 55-4920-424-13&P
c. Connecting the APU.
(1) Remove protective cap from fuel inlet filter fitting on APU, and connect flexible fuel supply line refer to
NOTE
Reconnect PCD air supply line and fuel supply line (Refer to Fig E-8) to Purge
Valve Assembly.
(2) Connect check stand control harness (P301)(Fig E-8) to harness receptacle on APU. Tighten harness
connector securely.
(3) Cap the large customer air tube with a unit made cap and coupling clamp P/N 12J16-150 (UH-60)
(4) (For U/EH-60 APU) Remove and plug the oil fitting attached to the accessory drive assembly next to the
fuel control system.
(5) Remove fuel control covering (Fig. E-9) to allow mounting of the starter generator.
1. Starter/Generator (P\W 23032-020) is used on the U\EH-60 APU.
2. Starter/Generator (P\N 20064-001) is used on the CH-47D APU.
3. The aircraft installed generator may remain attached to the APU.
(6) Install the appropriate auxiliary starter/generator (Fig. E-10) for your APU. (For U/EH-60 APU) First install
the starter/generator mounting bracket (Fig. E-9) to the accessory drive assembly with four nuts and washers, used to
hold the hydraulic starter on. With clamp, install starter/generator (P/N 23032-020) and tighten clamp nut. (For CH-47D)
First remove hydraulic starter and install electric starter/generator.
(7) Reinstall fuel control covering.
(8) Connect the four electrical leads from the control console to the starter/generator, observing proper
markings match.
(9) Install drain lines to the fuel drain and compressor drain. Route lines into a suitable waste fuel container.
CAUTION
Do not transport mobile check stand over rough terrain with APU installed.
Vibrations and Shock may damage vital APU parts.
3-5.
PRELIMINARY CHECKS.