4920-00-176-9236 ">
|
|
TM 55-4920-424-13&P
g. Connect battery.
h. Push in MAIN POWER circuit breaker. (See figure E-3.)
i. Move START-RUN-OFF switch to RUN.
j. Move BOOST PUMP switch to ON. Boost pump will operate and preservative oil will flow through line.
k. Move BOOST PUMP switch to OFF when preservative oil flows out of line.
I. Move START-RUN-OFF switch to OFF.
m. Pull MAIN POWER circuit breaker.
n. Disconnect battery.
o. Securely cap APU fuel supply line.
p. Reconnect tank-to-pump fuel supply line to tank fitting.
q. Remove fuel tank drain fitting and drain all preservative oil from tank. Reinstall drain fitting.
r. Wipe any spilled oil from stand surface and from stand components.
2-9.
PREPARATION FOR STORAGE.
2-10. The check stand must be prepared for storage, as follows:
a. Perform fuel system preservation in accordance with instructions in paragraph 2-8.
b. Disconnect power cable from battery.
c. Remove battery from stand; forward battery to an applicable storage area.
d. Remove fire extinguisher from stand; forward extinguisher to an applicable storage area.
e. Cover all cable connectors, and secure cables and harnesses to convenient structures.
f. Remove both started generators from stand; forward starter generators to an appropriate storage area.
g. Cover all openings on stand equipment.
Change 2 E-13
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |