Page Title: APU Testing
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-4920-424-13&P
o. If APU shuts down because of high exhaust gas temperature, the HIGH EXH TEMP light will illuminate. The
reason for this shutdown may be due to loading APU prior to attaining 100 percent rated speed, residual fuel
remaining in combustor, a restriction in air inlet or exhaust outlet, or a failure in the engine (resulting in increased
drag).  Correct these conditions accordingly.  Also, the fuel control may be out of adjustment.  Refer to
paragraph 3-10 for fuel control adjustment procedures.
p. If APU shuts down because of low oil pressure, the LOW OIL PRESS light will illuminate. This condition may be
caused by low oil level in the APU, malfunctioning oil pump, clogged oil filter, electrical discontinuity, or a
malfunctioning oil pressure switch. Refer to TM 55-2835-203-24 to correct these malfunctions.
Note
Rated speed (100 percent engine speed) corresponds to 4200 rpm of the
tachometer generator, 6000 rpm of the reduction drive output and 56,000 rpm of
the turbine.
3-13. APU Testing. After APU has automatically accelerated to rated speed, it is protected by three automatic safety
devices; a speed switch, a high exhaust temperature device, and a low oil pressure switch.
a. Speed Adjustment . After APU attains 100 percent rated speed (400-cycle ac) at no load, adjust fuel control rated
speed setting adjustment screw to obtain 102 percent engine speed. Run APU for approximately 10 minutes and
carefully check for fuel and oil leaks.
Note
Engine should shut down when rated speed is exceeded by 10 percent.  The
ENGINE SPEED indicator registers in percent.  The small hand makes one
revolution for each 10 percent.
b. Thermal Protective Device. It APU exceeds the temperature limit of 1120F (604.4C).
c. Low Oil Pressure Switch. The low oil pressure switch is set to shut down APU if decreasing oil pressure reaches
6 1 psig.
3-14. AC POWER OPERATION.
3-15. The mobile check stand may be used to furnish 115/200-volt, 400-cycle; ac power for aircraft preflight operations, or
other needs. A 50-foot power cable is provided with the check stand, and is equipped with a connector to engage the ac
power input receptacle on the aircraft.