TM 55-4920-325-14&P
Section I l . DESCRIPTION AND LEADING PARTICULARS
nating current (at) rebalancing bridge type, ca-
1-3. Description.
p a c i t a n c e substitution circuitry, calibration
The Model TF579 test set is manufactured by
circuitry with built-in standards of capacitance
Consolidated Airborne Systems, Inc., Carla Place,
and resistance, cable assemblies, and accessories.
L.I., New York. The test set provides a means to
determine the serviceability of aircraft (fixed and
1-4. Leading Particulars.
rotary wing) employing a capacitance type fuel
gaging system. The" test set consists of a single
Leading particulars, consisting of the technical
integral unit incorporating a transit case, direct
characteristics of the test set, are contained in ta-
current (dc) electrical resistance measuring cir-
ble 1-1. Cables and accessories supplied with the
cuit, capacitance measuring circuitry of an alter-
test set are listed in table 1-2.
Table 1-1. Leading Particulars.
Item
Characteristics
Power Requirements
105 to 125 Volts.
Voltage
200 to 236 Milliamperes.
Current
25 Watts.
Wattage
360 to 440 Hz.
Phase
Single Phase.
Range of Operation
Capacitance Measurement
Range
0 to 5000 uuf in four ranges.
Accuracy
0 to 1/2 scale = 0.25% of full scale.
1/2 to full scale = 0.5% of reading.
Maximum short circuit current
Less than 0.2 ampere.
X1, X3, X10, and X50.
Scale multipliers
Subdial, producing direct vernier readings to within
Vernier indicator scale
0.1%.
Precise tolerance capacitor, of known value, is in-
Self-calibrating feature
cluded within test set.
Insulation Resistance Measurement
0 to 10,000 megohms in four ranges.
Range
1/16 in. of scale reading.
Accuracy
Selector switch provides means for testing resistance
Measurement capabilities
between the following:
Unshielded conductor and compensator conductor to
ground.
Coaxial conductor to ground.
Coaxial conductor to unshielded conductor.
Coaxial conductor to compensator conductor.
33 microamperes at normal 33-volt operation.
Maximum short circuit current