(6) Remove air cleaner mounting tube (22) and two pipe plugs (23) from the housing (3).
Figure 3-25. Air Intake, Removal, Disassembly, Reassembly, and Installation.
c. Cleaning.
WARNING
Do not breathe cleaning solvent P-D-680 vapors for long periods of time or use solvent near
open flames. To avoid illness, explosion, or fire, only use solvent in well-ventilated areas away
from open flames.
(1) Clean all parts with cleaning solvent (item 4, Appendix C).
(2) Allow parts to dry.
d. Inspection.
(1) Inspect all parts for wear or damage.
(2) Be sure the face of the air shutoff valve is perfectly flat to assure a tight seal when it is in the
shutdown position.
e. Repair. Air intake assembly repairs are accomplished by the replacement of defective parts.
3-57