TM 55-1915-200-10
b. Set engine room exhaust fan port switch (14)
f. Close all valves in the cooling water piping
and circuit breaker (4) to OFF.
system for the ship service diesel generators. Refer to
FIGURE 2-220.
c. Set engine room supply fan port switch (10) and
circuit breaker (6) to OFF.
2-5.34.9. Firemain Shutdown.
d. Set engine room supply fan STBD switch (35)
NOTE
and circuit breaker (31) to OFF.
As long as any personnel are on board the
e. Set 150 AMP bus tie circuit breaker (46) to OFF.
vessel, the fire pump should remain online.
f. Set the following circuit breakers on the main
switchboard (FIGURE 2-219) to OFF.
a. Place OFF/ON switch (110) in OFF position on
(1) Steering Gear Hydraulic Pump (45).
Engine Room Motor Control Center (FIGURE 2-215).
(2) Distilling Plant No. 1 (47).
b. Set circuit breaker (108) to OFF position.
(3) Distilling Plant No. 2 (48).
CAUTION
(4) Main Engine Sump Heater Distribution
Panel (42).
Firefighting service onboard the vessel is
restricted to portable firefighting systems and
(5) Motor Control Center (60).
automatic Halon system. Leave firemain aligned
to be operable as soon as the fire/bilge pump
can be energized and pressure builds in the
firemain.
2-5.34.10. Final Shutdown.
a. Set engine room exhaust fan port switch (18,
2-577
|