TM 55-1915-200-10
m. Set bilge pump Number 1 port switch (71) and
circuit breaker (58) to OFF.
f. Set DISTILLING PLANT FEED WATER
BOOST PUMP STBD switch (97) to OFF and circuit
n. Set bilge pump Number 2 port switch (67) and
breaker (79) to OFF.
circuit breaker (59) to OFF.
g. Set DISTILLING PLANT FEEDWATER BOOST
o. Set AIR COMP Number 1 STBD switch (63) and
PUMP STBD switch (49) to OFF and circuit breaker (45)
circuit breaker (60) to OFF.
to OFF.
2-5.34.5. Compressed Air System. Close all valves in
2-5.34.4. Engine Room Motor Control Center.
compressed air system. Refer to FIGURES 2-216 and
2-217.
a. Set FUEL OIL TRANSFER PUMP #1 PORT
2-5.34.6. Emergency Switchboard. Set GENCKT BKR
switch (26) and circuit breaker (1) to OFF.
control switch MAN-OFF-AUTO (11, FIGURE 2-218) to
b. Set LUBE OIL TRANSFER PUMP switch (41)
OFF.
and circuit breaker (28) to OFF.
c. Set fuel oil purifier #1 port circuit breaker (38) to
2-5.34.7. Generator Number 2.
OFF.
d. Set fuel oil purifier #2 port circuit breaker (29) to
a. Set GEN #2 power switch (41, FIGURE 2-219)
OFF.
to OFF. Hold until generator stops operating.
e. Set fuel oil purifier port circuit breaker (30) to
b. Set GENERATOR #2 circuit breaker (61) to
OFF.
OFF.
f. Set gear oil cooling pump port switch (56) to
OFF and circuit breaker (43) to OFF.
2-5.34.8. Generator Number 1.
g. Set gear oil cooling pump STBD switch (53) and
circuit breaker (44) to OFF.
a. Set GEN #1 power switch (45, FIGURE 2-219)
h. Set main engine pre-lube pump oil pump port
to OFF. Hold until generator stops operating.
switch (104) and circuit breaker (77) to OFF.
b. Set GENERATOR #1 circuit breaker (62) to
i. Set main engine pre-lube oil pump STBD switch
OFF.
(100) and circuit breaker (78) to OFF.
c. Shift metal locking bar (50) to left.
j. Set SLUDGE PUMP STBD switch (85) and
d. Set shore power circuit breaker (51) to ON.
circuit breaker (22) to OFF.
Observe shore power light (6) is lit.
k. Set air conditioning cooling water pump Number
e. Close all valves in fuel oil system piping. Refer
1 switch (114) and circuit breaker (107) to OFF.
l. Set ballast pump STBD switch (75) and circuit
breaker (57) to OFF.
2-563
|