Click here to make tpub.com your Home Page

Page Title: Manual Priming Startup.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-1915-200-10
NOTE
a. Unscrew and remove manual prime inlet plug
If engine is cold, advance CHOKE
(10, FIGURE 2-177, Sheet 2 of 3) from priming inlet.
control (6) fully clockwise (closed),
b. Fill pump with water until filler cap is full,
then half open as engine starts, and
replace plug in priming inlet.
fully open for running.
c. Place OFF-START-RUN switch (3, Sheet 1 of 3)
e. Depress and hold START pushbutton (5) until
in START position.
engine starts.  Adjust choke and speed controls as
d. Advance SPEED control (7) in clockwise
required.
direction, 1/4 full throttle.
CAUTION
NOTE
Do not allow pump to run more than
If engine is cold, advance CHOKE
2 minutes without water flowing.
control (6) fully clockwise (closed),
Lack of cooling water could cause
then half open as engine starts, and
severe impeller and exhaust system
fully open for running.
damage.
e. Depress and hold START pushbutton (5) until
f. Rotate water discharge valve (8, FIGURE 2-
engine starts.  Adjust choke and speed controls as
177, Sheet 2 of 3) counterclockwise to fully CLOSED
required.
position.
CAUTION
NOTE
Do not allow pump to run more than
If suction lift is 20 feet or less, push
2 minutes without water flowing.
in  and  keep  firm  continuous
Lack of cooling water could cause
pressure on PRIME pushbutton (4,
severe impeller and exhaust system
Sheet 1 of 3) until pump is primed.
damage.
g. Open slowly by rotating water discharge valve
f. Open water discharge valve (8, Sheet 2 of 3)
(8, Sheet 2 of 3) clockwise until indicating pressure on
slowly and advance engine speed control (7, Sheet 1 of
gauge and advance speed control (7, Sheet 1 of 3) as
3) as required to attain desired pumping pressure.
required.
g. Place OFF-START-RUN switch (3) in RUN
h. Release PRIME pushbutton (4) after priming
position.
pump.
h. Rotate
CHOKE
control
(6)
to
full
i. Place OFF-START-RUN switch (3) in RUN
counterclockwise position.
position.
2-5.27.3. Turn-Off Instructions.
j. Rotate
CHOKE
control
(6)
to
full
a. Rotate SPEED control (7, FIGURE 2-177, Sheet
counterclockwise, OFF position.
1 of 3) to full counterclockwise OFF position.
2-5.27.2. Manual Priming Startup.
b. Place OFF-START-RUN switch (3) in OFF
position.
2-493

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business