2-5.14.4. Refueling Operation.
h. Close manifold discharge valves (9, FIGURE
2-147) as tanks fill to required level.
WARNING
i. Stop pumping operation when all tanks have
filled to required level.
Fueling operations present a serious
fire hazard.  Ensure NO SMOKING
j.
Close all valves in fuel oil transfer piping
signs  are  placed  at  appropriate
system.
locations throughout vessel and/or
decks.
Make
announcements
2-5.14.5. Defueling Operation.
through public address system that
fueling operations are in progress.
WARNING
Take other precautions as required
by U.S. Army Regulations.
Defueling  operations  present  a
serious fire hazard.
Ensure NO
a.  Align fuel oil transfer piping system by
SMOKING  signs  are  placed  at
closing all valves (FIGURE 2147).
appropriate  locations  through-out
vessel
and/or
decks.
Make
NOTE
announcements
through
public
address  system  that  defueling
Isolation valves (15) are reach rods
operations are in progress.  Take
operated with a T-handle from the
other precautions as required by U.S.
main deck just forward of frame 84
Army Regulations.
port side.
These valves will be
normally open.
a. Turn on fuel oil transfer pump circuit breaker
(1, FIGURE 2-103, Sheet 1 of 7) at the engine room
b. Open fuel oil tank isolation valves (15).
motor control center.
c. Open fuel oil manifold discharge valves (9)
b.  Align Fuel Oil Transfer piping system by
as required.
closing all valves (FIGURE 2-147).
d. Open discharge valve (7) to fuel oil manifold.
c.  Connect discharge hose to fueilng station
(71, FIGURE 2-151, Sheet 2 of 3) located on main deck.
e.  Open discharge/suction valve (6) to main
Open fueling station stop valve (6, FIGURE 2-147).
deck fueling station.
d.  Open discharge/suction valve (6) to main
f. Connect fueling hose to fueling station hose
deck fueling station.
connection (71, FIGURE 2-151, Sheet 2 of 3), open
fueling station valve (6, FIGURE 2-147), start pumping
e. Open inline stop valve (5).
operations.
f. Open fuel oil pump discharge valve (23).
g. Sound tanks (33, 42, and 76, FIGURE 2-151,
Sheet 2 of 3), located on main decks. Do not overfill
g. Open gauge cutout valve (18).
tanks.
h.
Open fuel oil transfer pump suction valve
(22).
2-431