2-5.8.12. After Shutdown Bow Thruster Compartment
.
b. Check lubricating oil day tank level (3, FIGURE
a. Secure bow thruster fuel oil system piping
c. If necessary, add oil at expansion tank fill port
(4).
(1) Close fuel oil day tank outlet valve (3).
2-5.9.  Halon 1301 Fire Suppression Operation  The
.
Halon 1301 Fire Suppression System consists of engine
(2) Close inline stop valve (7).
room, bow thruster room, emergency generator room and
the paint locker.
NOTE
2-5.9.1. Engine Room Halon Operation.
Two  fuel  oil  filters  are  installed.
Secure fuel filter inlet and outlet valves
WARNING
in use.
 A waiting period of at least 30
minutes is required to ensure that
(3) Close fuel oil filter inlet valve (9) or (14).
the area has cooled and the fire will
not
re-ignite
upon
entry
of
(4) Close fuel oil filter outlet valve (11) or (12).
personnel. When a hatch or door is
opened or the ventilation system is
restarted, oxygen enters the area
b. Secure engine cooling water system piping
and dilutes the Halon.
Do not re-enter the space where
(1) Close cooling water inlet valve (7) to keel
Halon has been used to extinguish a
cooler.
fire  unless  wearing  an  oxygen
breathing apparatus (OBA).
(2) Close cooling water outlet valve (8) from
keel cooler.
Wear the OBA until the atmosphere
is certified safe. Anyone suffering
(3) Close  cooling  water  expansion
tank
from the toxic effects of Halon 1301
discharge valve (4) to bow thruster engine.
vapor should immediately move, or
be moved, to fresh air.
(4) Close cooling water expansion tank fresh
water fill valve (1).
All personnel must leave the engine
room immediately upon activation
of the Halon 1301 Fire Suppression
c. Turn off compartment air supply by pressing
System alarm.  System discharges
STOP button (5, FIGURE 2-137) on BOW THRUSTER
within 25 seconds after activation.
COMPARTMENT VENTILATION SYSTEM controller.
Evacuating personnel must secure
the doors as they evacuate the area.
2-5.8.13. After Shutdown Port Deck Stores Compartment
.
a. Surface Pull Box.
a. Secure  bow
thruster
lubricating
oil
system
(1) Close gear oil expansion tank inlet valve (1)
from bow thruster.
(2) Close gear oil expansion tank outlet valve
(7) to bow thruster.