|
|
TM 55-1915-200-10
B
Table 2-2. Operator/Crew Preventative Maintenance Checks and Services
EQUIPMENT NOT READY/AVAILABLE
- BEFORE D - DURING A - AFTER W - WEEKLY M - MONTHLY Q - QUARTERLY S/A SEMI ANNUALLY AN - ANNUALLY
IF
T/A - TRIENNIALLY
ITEM
B
D
AWM
Q S/A AN T/A
ITEMS TO BE INSPECTED
CHECK FOR
ACTION
PMC
NMC
NUMBER
X
Exhaust Hose
Check that exhaust hose and gaskets are tight
Tighten as necessary.
Exhaust system
and sealed properly with no leaks.
Replace gaskets as
leaks.
necessary.
WARNING
DO NOT OPERATE PUMP IN CLOSED AREA
WITHOUT EXHAUST HOSE CONNECTED AND
ROUTED SAFELY TO OUTSIDE FRESH AIR.
X
Fuel Line
Check hose connections for proper direction of
Adjust as necessary.
Class III leaks.
fuel flow.
X
Priming Pump Oil
Check oil level.
Add oil as necessary.
Low oil level.
X
Spark Plugs
Check condition of spark plugs.
Replace as necessary.
X
Pump Exterior
Visually inspect pump for damage and condition. Repair damage as
necessary.
X
X
Fuel Tank
Check level of fuel.
Add fuel as necessary.
NOTE
Fill gas tank with MIXTURE of two (2) cans of BIA-
TC-W oil and six (6) gallons of 090 octane
gasoline.
94
Portable Fire Fighting
Pump Model P-100
(If Equipped)
CAUTION
ONLY USE DIESEL FUEL IN THIS PUMP OR
DAMAGE TO EQUIPMENT WILL OCCUR.
Tighten as necessary.
Connections will
X
X
Suction Hose
Check hose connections for tightness at pump
not properly
and foot valve strainer. Check gaskets for
Replace gaskets as
attach.
deterioration and dry rot.
necessary.
NOTE
The suction hoses must be supported at the inlet
of the pump.
Use spanner wrench to tighten all suction hose
connections. The slightest air leak will cause the
pump to cavitate.
LSV PMCS
Change 12
2-295
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |