TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Main Switchboard (FIGURE 2-19) - continued
58
EMER GEN RM
Provides 150 ampere automatic
DIST PNL
trip protection.
3P 460V 150AT
59
BUS TIE
Ties ship's service generator
CKT BKR
bus to emergency generator bus
3P 460V 150AT
for normal operation. Failure
of both ship's service generators
will open circuit breaker. Emergency
generator will only operate mandatory
emergency circuits.
60
MOTOR CONTROL
Provides 400 ampere automatic
CENTER
trip protection.
3P 460V 400AT
61
GENERATOR #2
Provides 450 ampere automatic
CKT BKR
trip circuit protection.
3P 460V 450AT
62
GENERATOR #1
Provides 450 ampere automatic
CKT BKR
trip circuit protection.
3P 460V 450AT
2-95
|