TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Engine Room Motor Control Center (Figure 2-18) - continued
1
A.C. VOLTS Meter
Indicates voltage generated by
number 1 generator or the bus.
2
Phase Selector Switch
Selects one of three phases of
number 1 generator displayed
on A.C. AmpERES meter.
3
A.C. AmpERES
Meter Indicates amperage of phase
selector switch of generator
number 1.
4
GENERATOR NO. 1
Indicates (white light) power
POWER AVAILABLE
available from generator number 1.
5
A.C. KILOWATTS
Meter Indicates amount of kilowatts
drawn from number l generator.
6
SHORE POWER
Indicates (amber light) shore power
AVAILABLE
is available.
7
HERTZ Meter
Indicates hertz of number 1
or number 2 generator.
8
Selector Switch
Selects number 1 or number 2
generator displayed on hertz meter.
9
A.C. KILOWATTS
Meter Indicates amount of kilowatts
drawn from number 2 generator.
10
Phase Selector Switch
Selects one of three phases of
number 2 generator displayed
on A.C. AmpERES meter.
11
A.C. AmpERES Meter
Indicates amperage of phase
as selected by phase selector
switch of generator number 2.
12
A.C. VOLTS Meter
Indicates voltage generated by
number 2 generator.
13
BUS GEN 2 SWITCH
Selects voltages across phases
1, 2, or 3 of generator number 2, or
voltages across phases 1, 2, or 3 of
the bus.