TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Engine Room Motor Control Center (FIGURE 2-18)
1
Circuit Breaker
Protects #1 port fuel oil transfer
(15 Amp)
pump motor from amperage overload.
2
Circuit Breaker
Protects #2 port fuel oil transfer
(15 Amp)
pump motor from amperage overload.
3
Circuit Breaker
Protects port engine room exhaust
(15 Amp)
fan from amperage overload.
4
Circuit Breaker
Protects starboard engine room
(15 Amp)
exhaust fan from amperage overload.
5
SLOW RUN
Green light indicates port engine
room supply fan is in slow running mode.
6
Circuit Breaker
Protects port engine room supply
(40 Amp)
fan from amperage overload.
7
Reset Pushbutton
Resets slow run contacts of port
engine room supply fan motor controller.
8
Reset Pushbutton
Resets fast run contacts of port
engine room supply fan motor controller.
9
STOP SLOW FAST
Switches port engine room supply
fan motor to slow, stop, or fast run
condition.
10
UV RESET
Resets port engine room supply fan
motor controller after under voltage
condition (loss of power or low
voltage).
11
FAST RUN
Green light indicates port engine
room supply fan motor in fast running
mode.
12
Reset Pushbutton
Resets contacts of starboard engine
room exhaust fan motor controller.
13
STOP
Pushbutton to STOP starboard engine
room exhaust fan motor.
2-69
|