TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Engine Room Console (FIGURE 2-16) - continued
90
ASSISTANCE
When an alarm is detected at the ERC,
NEEDED
the audible relay is energized auto-
matically. The operator at the ERC
presses the acknowledge pushbutton to
de-energize the audible device. If the
operator at the ERC is unable to acknow-
ledge an alarm for a period longer than
30 seconds, the Assistance Needed relays
will energize. Assistance Needed indi-
cators and sounding of the audible
devices will activate at all engineer-
ing stateroom Watchcall/Assistance
Needed panels and in passageways near
the engineering mess and recreation
room. The alarm can only be silenced by
depressing the Acknowledge pushbuton at
the ERC. The Assistance Needed system
may also be activated by depressing the
Assistance Needed pushbutton on the
master panel.
91
HIGH
Indicates high level of water in fresh
LEVEL
water tank.
92
LOW
Indicates low level of water in fresh
LEVEL
water tank.
93
ALM. SILENCE
Pushbutton silences audible alarm.
94
Level Indicator
Indicates current water level in fresh
water tank.
95
POWER
Indicates power is on for water level
indicator.
96
CALIBRATE
Adjusts needle for accurate readings.
97
ON-OFF-FULL REF
ON activates indicator, OFF deactivates
indicator, and FULL REF causes needle to
go to FULL.
98
P.M.E.
Light illuminates at 9 psi.
LOW OIL PRESS.
AUTO SHUTDOWN
99
P.M.E.
Light illuminates at 210F.
HIGH OIL TEMP.
2-60
|