TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Engine Room Console (FIGURE 2-16) - continued
71
EOT STBD
The engine order telegraph (EOT) system
(See separate panel)
is used to communicate the desired pro-
peller shaft speed and direction for
each shaft, from the pilothouse console
(PHC) to the engine room console (ERC)
when the PHC is not in direct control of
the propulsion plant. (See FIGURE 2-
10.)
72
SHAFT RPM STBD
Indicates RPM of the starboard shaft.
73
SHAFT RPM PORT
Indicates RPM of the port shaft.
74
EOT PORT
See Figure 2-10.
(See separate panel)
75
CONTAIR TRANSF
Transfers pneumatic control to the
pilothouse console.
76
GENERATOR NO. 1
Indicates the temperature of number
EXHAUST
1 generator exhaust.
77
GENERATOR NO. 2
Indicates the temperature of number
EXHAUST
2 generator exhaust.
78
STBD MAIN ENGINE
Indicates the temperature of star-
EXHAUST STACK
board main engine exhaust stack.
79
STBD MAIN ENGINE
Indicates temperature of starboard
EXHAUST
main engine exhaust manifold.
80
PORT MAIN ENGINE
Indicates temperature of starboard
EXHAUST
main engine exhaust manifold
81
PORT MAIN ENGINE
Indicates temperature of port
EXHAUST STACK
main engine exhaust stack.
82
POWER
Turns power ON or OFF to master
ON/OFF
watchcall and assistance needed
panel. When the power is ON the
pushbutton will be illuminated.
83
CANCEL
Silences audible device and turns
off illuminated call button at both
the master watchcall and assistance
needed panel and called engineer's
stateroom panel.
2-58
|