Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Marine Fire Detector Panel (FIGURE 2-13)
1
Alarm Bell
Rings when pilothouse smoke or
thermal alarm has activated.
2
Horn and Strobe Alarm
Activates upon detection of a manual
smoke or thermal alarm in engine room.
Horn and strobe alarm can be silenced at
main control panel only.
3
PANEL RESET
Provides system lamp test and
resets system after alarm has been
silenced.
4
ALARM SILENCE Pushbutton
Silences audible fire alarm.
5
TROUBLE SILENCE Pushbutton
Silences trouble alarm.
NOTE
Red lights indicate fire in the zone and amber lights indicate trouble.
6
ZONE 7
Indicates fire or trouble in STBD
STBD-BOW STORAGE
bow storage and paint locker.
& PAINT LOCKER
7
ALARM TEST
Indicates activation of a zone
test switch.
8
ZONE 8
Indicates fire or trouble in STBD
STBD AFT MISC SPACES
aft miscellaneous spaces.
9
ZONE 10
Indicates fire or trouble in engine
ENGINE ROOM
room.
10
ZONE 12
Indicates fire or trouble in steer-
STEERING COMPARTMENT
ing compartment and passageway.
& PASSAGEWAY
11
SPARE
Spare
12
ZONE 11
Indicates fire or trouble in
CONTROL ROOM
control room.
2-37
|