TM 55-1915-200-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Navigation Light Panel (FIGURE 2-12) - continued
4
MASTHEAD LGT ON
Green indicator light that is on when
forward masthead light circuit is
closed.
5
MASTHEAD LGT AFT ON
Green indicator light that is on when
aft masthead light circuit is closed.
6
STERN LGT ON
Green indicator light that is on when
stern light circuit is closed.
7
ANCHOR LGT FWD ON
Green indicator light that is on when
forward anchor light circuit is closed.
8
ANCHOR LGT AFT ON
Green indicator light that is on when
aft anchor light circuit is closed.
9
UPPER NUC LGT 1 ON
Green indicator light that is on when
upper not under command light number 1
circuit is closed.
10
UPPER NUC LGT 2 ON
Green indicator light that is on when
upper not under command light number 2
circuit is closed.
11
LOWER NUC LGT 1 ON
Green indicator light that is on when
lower not under command light number 1
circuit is closed.
12
LOWER NUC LGT 2 ON
Green indicator light that is on when
lower not under command light number 2
circuit is closed.
13
Toggle Switch
Two position switches for on or fail
position for each light. Toggle is
placed in FAIL position to silence
alarm, or for light to be off. Place in
ON position to turn light on.
14
LOWER NUC LGT 2 FAIL
Red indicator light that is on when
lower not under command light number 2
circuit is open.
15
LOWER NUC LGT 1 FAIL
Red indicator light that is on when
lower not under command light number 1
circuit is open.
2-35
|