TM 55-1915-200-10
ERC when the PHC-78 not in direct control of the main
pressing the manual assistance needed button on the
master panel. When energized, the assistance needed
engines. The system consists of a selector switch
indicating lamps and bells mounted both at the ERC and
relay enables indications and audible devices in the
engineering mess and the recreation room. The relay is
at the PHC. The EOT bells ring at both locations if the
deenergized by depressing the acknowledge (ACK)
selector switch at the ERC does not match the position
pushbutton on the ERC or releasing the manual
of the selector switch at the PHC or if the PHC EOT
assistance needed pushbutton on the master panel.
selector switch is positioned from one direction to
another direction without the shaft coming to a stop. If
1-10.6.9. Attendance Monitor System. The attendance
the positions of the EOT selector switches at both
locations are in the same position, the EOT bells are
monitor system (also known as the dead man alarm)
silent.
enables the PHC operator to verify that the ERC
operator is attentive. The system is activated by the
1-10.6.8. Watchcall/Assistance Needed System. The
PHC operator and is timer controlled. Every 30 minutes
the ERC operator is given two minutes to respond to an
watchcall/assistance needed system provides remote
indication and audible call at the ERC. If this is done
alarms in various vessel locations which alert personnel
the timer restarts. If it is not done in the two minutes
in the event the ERC operator does not respond to an
provided, an alarm sounds at the PHC.
alarm within a specific time. The system also provides
the means to call an engineer, in a stateroom, to the
1-10.6.10. Marine Fire and Smoke Detection System.
engineer's turn on watch.
The marine fire and smoke detection system (FO-2)
1-10.6.8.1. Watchcall. The watchcall system notifies an
sounds an alarm when fire or smoke is detected. The
engineer of his turn on watch. The system is activated
system consists of a main fire panel, smoke and heat
by pressing an engineering call button at the master
detectors, manual fire alarm stations, and associated
panel. Depressing the button energizes a relay in the
alarms. The smoke and heat detectors are arranged in
master panel which enables an indication and an
12 zones throughout the ship. When a fire or smoke
audible device at both the ERC and the selected state
condition is detected, the associated detector sends an
room panel. Pressing the cancel button at either
alarm signal via a junction box to the main fire panel.
location will deenergize the relay which inhibits the
The alarm panel displays indications of the alarm by
indications and audible devices.
zone, sounds alarm bells at the pilot house and engine
room, enables audible and strobe alarms on the
1-10.6.8.2. Assistance Needed. The assistance needed
intrusion fire alarm panels, and enables a visual alarm
strobe light in the engine room. If main generator power
system notifies offwatch engineers that the ERC
drops below 95 volts, the system is transferred from
operator needs assistance. The system is activated
main generator power to emergency generator power.
when the ERC alarm system detects an alarm condition
and energizes an audible relay. The energized audible
1-10.6.11.
Intrusion/Fire Alarm System.
The
relay enables a 30 second delay timer in the master
panel. If the ERC alarm is not acknowledged before the
intrusion/fire alarm system indicates unauthorized entry
timer expires, the assistance needed relay in the master
into
the
secure
radio
room
and
arms
panel energizes. The relay may also be energized by
1-79
|