q. Install pipe reducer (26) on pipe elbow (27) and secure.
r.
Install nonmetallic hose assembly (23) female adapter (25) on pipe reducer (26) and secure. Connect other end
of nonmetallic hose assembly (23) male adapter to high pressure regulator assembly and secure.
s.
Install hose adapter (31) on lower RO module (6) and plug (18)-and secure.
t.
Install nonmetallic hose (33) with hose clamps (32) on hose adapter (31) and secure nonmetallic hose (33) on
hose adapter (31) with hose clamp (32).
u. Install hose tee (35) on nonmetallic hose (33) and secure with hose clamp (32).
v.
Install nonmetallic hose (24) and hose clamp (34) on hose tee (35) and secure hose clamp (34). Connect other
end of nonmetallic hose (24) to brine manifold assembly and secure with hose clamp.
w. Install hose adapter (31) on upper RO module (6) ONBOARD END end plug (18) and secure.
x.
Install nonmetallic hose (37) with hose clamp (32) on hose adapter (31) and secure hose clamp (32).
y.
Install other end of nonmetallic hose (37) with hose clamp (36) on hose tee (35) and secure hose clamp (36).
z.
Install pipe nipple (2) on upper RO module (6) OUTBOARD END end plug (18) and secure.
aa. Install pipe elbow (38) on pipe nipple (2) and secure.
ab. Install pipe nipple (39) on pipe elbow (38) and secure.
ac. Install pipe elbow (1) on pipe nipple (39) and secure.
ad. Install pipe reducer (3) on pipe elbow (1) and secure.
ae. Install nonmetallic hose assembly (5) female adapter (4) on pipe reducer (3) and secure.
af. Connect other end of nonmetallic hose assembly (5) male adapter to high pressure pump assembly and secure.
ag. Close appropriate inlet feedwater gate valve (2, FIGURE 2-31, Sheet 1).
ah. Startup watermaker. Refer to TM 55-1905-223-10.
ai. Observe pressure vessel assembly for leaks. Repair as necessary.
aj. Remove "Out of Service, Do Not Operate" tag.