TM 55-1905-223-24-7
2-31. Replace/Repair Pressure Vessel Assembly. (FIGURE 2-32)
This task covers: a. Service,
b. Removal,
c. Repair,
d. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
Service task requires unit
to be in operation.
Kit, cleaning/preservation chemicals
06C-OVM500-000
Materials/Parts
Preformed packing P/N 2-116
Preformed packing P/N 2-228
Scrub brush, Item 8, Appendix C
Pressure vessel assembly P/N 7383
Nonmetallic hose P/N PVTBF025
Nonmetallic hose assembly P/N PG-H00381
Seawater element P/N SW-2540
Reverse osmosis pressure vessel P/N 13A-VM2540-012
SERVICE
a. To change the actual flow to equivalent flow at 25C:
(1)
Measure feedwater temperature.
(2)
Find the corresponding correction factor in Table 2-3.
(3)
Read the product water flowmeter.
(4)
Multiply the correction factor times the flow rate. This is the equivalent flow for 250C.
b. To correct actual flow at a given temperature to an equivalent rate at a desired temperature:
(1)
Measure actual feedwater temperature.
(2)
Look up corresponding correction factor for the actual temperature.
2-107
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |