2-29. Replace Brine Manifold Assembly. (FIGURE 2-30)
This task covers: a. Removal,
b. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
Desalinator shut down (TM 55-1905-
223-10) and tagged "Out of Service -
Do Not Operate."
Materials/Parts
Warning tag, Item 11, Appendix C
Scrub brush, Item 8, Appendix C
REMOVAL
a. Close appropriate inlet feedwater gate valve (2, FIGURE 2-30, Sheet 1).
NOTE
Contact Intermediate Direct Support maintenance level to disconnect the
following items before removal.
b. Tag and disconnect salinity probe (11, FIGURE 2-30, Sheet 2) wiring from water quality monitor terminals 4 and 5.
c.
Remove nonmetallic hose (24) from brine flowmeter by loosening hose clamp at that end.
d. Remove nonmetallic hose (2) from cleaning valve assembly by loosening hose clamp at that end.
e. Remove nonmetallic hose (22) from micron filter assembly air bleedoff connection by loosening hose clamp at that
end.
f.
Remove nonmetallic hose (20) from solenoid valve assembly by loosening hose clamp at that end.
g. Remove nonmetallic hose (18) from solenoid valve assembly by loosening hose clamp at that end.
2-99