2-27. Replace/Repair Solenoid Valve Assembly. (FIGURE 2-28)
This task covers: a. Removal, b. Disassembly, c. Repair, d. Assembly,
e. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
Watermaker assembly shut down.
Refer to TM 55-1905-223-10.
Watermaker assembly tagged
Materials/Parts
"Out of Service, Do Not Operate."
Nonmetallic hose P/N PVT3F025
REMOVAL
a. Close appropriate inlet feedwater gate valve (2, FIGURE 2-28, Sheet 1).
b. Disconnect three nonmetallic hoses by removing hose clamps and hoses (3, FIGURE 2-28, Sheet 2) at brine
manifold assembly and product flowmeter assembly.
c.
Tag and disconnect wiring inside spiral wiring wrap (2) at water quality water monitor assembly.
d. While supporting solenoid valve assembly, remove two machine screws (1) from mounting bracket (9) and remove
solenoid valve assembly from watermaker.
DISASSEMBLY
a. Loosen three hose clamps (4).
b. Remove three nonmetallic hoses (3) and three hose clamps (4) from elbow hose adapters (6) and hose adapter (8).
c.
Loosen cap (5) and remove mounting bracket (9) from solenoid valve (7).
d. Remove two hose elbow adapters (6) from solenoid valve (7).
e. Remove hose adapter (8) from solenoid valve (7).