TM 55-1905-223-24-7
2-26. Replace/Repair High Pressure Regulator Assembly. (FIGURE 2-27)
This task covers: a. Adjustment, b. Removal, c. Repair, d. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
RO desalinator should be operating
for the ADJUST task. Refer to
TM 55-1905-223-10.
For DISASSEMBLY and ASSEMBLY tasks
RO desalinator should be shut down.
Materials/Parts
Refer to TM 55-1905-223-10.
Plastic dash panel removed.
Dial indicating pressure gage,
Refer to paragraph 2-22.
P/N 09G-001000-025
High pressure regulator assembly removed.
Nonmetallic hose P/N PVTBF075
Refer to paragraph 2-22.
Nonmetallic hose P/N PVTBF050
RO desalinator tagged "Out of Service,
High pressure hose assembly
Do Not Operate."
P/N 7392
Globe valve P/N SS-43F4
Fluid pressure regulating valve
P/N 03R-VM1300-005
Warning Tag, Item 11, Appendix C
ADJUSTMENT
a. Slowly turn adjustment nut (1) clockwise.
b. Watch high pressure gauge (3) for rise in pressure.
c.
When gauge reads 800 psi, no further adjustment is required.
REMOVAL
a. Remove two hose clamps (10 and 15).
b. Remove two nonmetallic hoses (2 and 9).
c.
Remove high pressure hose assembly (8) by disconnecting male adapter end from reducer coupling (7).
d. Unscrew dial indicating pressure gauge (3) and remove from pipe cross (6).
e. Remove reducer coupling (7) from pipe nipple (5).
2-87
|