TM 55-1905-223-24-7
i.
Turn tension adjustment (10) clockwise to tighten V-belt tension or counterclockwise to lessen tension.
j.
Check V-belt (5) tension again [step (h)].
k.
Adjust V-belt (5) tension [steps (h), (i) and (j)] as necessary.
1. Install reducer bushing (14) with hose elbow (19) attached in pump outlet port.
m. Install high pressure hose assembly (1) female adapter end on hose elbow (19) and secure.
n. Install reducer bushing (13) with nipple and hose tee (18) attached in pump. inlet port.
o. Install nonmetallic hose (12) and hose clamp (11) on hose elbow (17) and secure hose clamp (11).
p. Position pulley guard (6, FIGURE 2-14, Sheet 2) in main frame assembly (3) and secure angle brackets (5, 7, and 8)
with eleven machine screws (4).
q. Position louvered panel (1) on left side of unit and secure with ten machine screws (2).
r.
Remove oil filler plug (15, FIGURE 2-14, Sheet 3) and check axial pistons pump oil level on dipstick on plug.
(1) If oil is at line on oil filler plug dipstick, proceed to step (u).
(2) If oil is below line on oil filler plug dipstick, proceed to step (s).
s.
Place funnel into oil filler plug (15) opening on axial pistons pump (16).
t.
Fill with oil to line on oil filler plug (15) dipstick.
u. Replace oil filler plug (15).
v.
Open appropriate inlet feedwater gate valve (2, FIGURE 2-14, Sheet 1) on unit.
w. Start up RO desalinator unit. Refer to TM 55-1905-223-10.
2-63
|