TM 55-1905-223-24-7
2-19.
Replace Alternating Current Motor.
This task covers: a. Removal,
b. Replacement.
INITIAL SETUP:
Tools
Equipment Condition
Tool kit, general mechanic's,
RO desalinator shut down. Refer
to TM 55-1905-223-10.
Standard puller, P/N ST 647
RO desalinator tagged "Out of Service,
Do Not Operate."
Materials/Parts
Alternating current motor, P/N M3611T
REMOVAL
Remove alternating current motor (high pressure pump).
a. Close appropriate inlet feedwater gate valve (2, FIGURE 2-12, Sheet 1) for RO desalinator unit under
maintenance.
b. On left side of RO desalinator unit, remove ten machine screws (2, FIGURE 2-12, Sheet 2) and remove louvered
panel (1) from unit.
c. On main frame assembly (3) remove eleven machine screws (4) from angle brackets (5, 7, and 8) and remove
pulley guard (6) from main frame assembly.
d. On alternating current motor (2, FIGURE 2-13) remove four screws (3) from motor terminal box (1) access cover
and remove cover.
e. Tag and disconnect red, black and white power cord leads from inside motor terminal box (1).
f. Disassemble outlet conduit elbow (8) and outlet conduit (9) from terminal box (1) and remove power cable.
g. Assemble outlet conduit (9) and outlet conduit elbow (8) to terminal box (1).
h. Replace access cover on ac motor terminal box (1) and secure with four screws (3).
i. Loosen four hexagon nuts (5) on adjustable base (6) that pump (4) rests on.
j. Turn tension adjustment (7) counterclockwise until slots contact threaded studs.
2-54
|