TM 55-1905-223-24-7
p. Position preformed packing (16) to base of vessel.
q. Replace lower rim clenching clamp (18) and secure with clamp nut (24), tapping the circumference of clamp while
tightening.
r. Place clean or new fluid filter element (17) in vessel (32), ensuring that top of filter is up.
s. Assemble machine thread plug (4), preformed packing (5), fitting (6), gaskets (7 and 8), and insert through hole in
lid (1), and secure with hexagon nut (19) from bottom of lid.
t. Place upper preformed packing (16) on vessel and position lid (1).
u. Position rim clenching clamp (15) and secure with upper clamp nut (23), tapping circumference of clamp while
tightening.
REPLACEMENT
a. Position micron filter assembly (FIGURE 2-4) in watermaker; align base (10) mounting holes with desalinator
mounting holes.
b. Secure micron filter assembly base (10) with four hexagon nuts (21), lockwashers (22), and machine screws (23).
c. Attach nonmetallic hose (2) to air bleedoff connection on lid (1) and secure with hose clamp (3).
d. Attach nonmetallic hoses (26 and 29) and hose clamps (25 and 30) to elbow hose adapters (27 and 28) on hose
tee (20) and secure hose clamps (25 and 30).
e. Attach nonmetallic hose (13) and hose clamp (14) to elbow hose adapter (11) and secure hose clamp (14).
f. Open appropriate feedwater gate valve (2, FIGURE 2-3, Sheet 1) for unit.
g. Start up watermaker. Refer to TM 55-1905-223-10.
h. Check micron filter assembly (FIGURE 2-4) for leaks at all connections.
i. Remove "Out of Service, Do Not Operate" tag.
2-28
|