SECTION IV. UNIT TROUBLESHOOTING
2-9.
Troubleshooting. Both a symptom index and a troubleshooting table are provided. The symptom index will help
you locate the information you need for troubleshooting.
SYMPTOM INDEX
Troubleshooting
Procedure
HIGH PRESSURE PUMP
Noisy operation/excessive vibration
Item 9
Volume/pressure falls off
Item 8
LOW PRESSURE GAUGE
Indicates vacuum
Item 1
Indicates 0 psi
Item 2
PRESSURE
No high pressure; low pressure
gauge reads positive pressure
Item 3
PRODUCT FLOWMETER
Indicates low flow rate
Item 5
PRODUCT WATER
Water quality monitor QUALITY LOW
red lamp lit
Item 4
Salty
Item
RO UNIT
Water pulsations
Item 10
Will not prime
Item 7
Table 2-2 lists the common fault conditions that may be found during operation or maintenance of the equipment. Look for
causes and do corrective actions in the order listed. This manual cannot list every symptom that may show up, and it
cannot list all the possible causes and corrective actions. If a symptom is not listed, or if it keeps up after you have
performed the corrective actions, notify your supervisor.