TM 55-1905-223-24-4
i.
Install the rod cap and capscrews to the connecting rod. Alternately, tighten the two capscrews.
FIGURE 3-87. Install Rod Caps.
FIGURE 3-88. Tighten Capscrews Sequence
.
STEP
26 ft-lb (35 N )
1
m
51 ft-lb (70 N )
2
m
73 ft-lb (100 N )
3
m
j.
Measure the side clearance between the connecting rod and crankshaft. Th side clearance limits are 0.0004 to
e
0.012 inch (0.1 to 0.3 mm).
FIGURE 3-89. Measure Side Clearance.
k.
Check that crankshaft rotates freely as the rod caps are installed.
l.
Reference equipment conditions for further assembly replacements.