![]() TM 55-1905-223-24-4
3-10. Repair Instrument Panel Assembly . (FIGURE 3-3)
This task covers:
a. Disassembly,
b. Repair,
c. Assembly.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, electrician's,
Equipment secured and tagged "Out of
Service" (TM 55-1905-223-10).
Digital multimeter,
Door assemblies removed
(Para. 2-14 and 2-15).
Instrument panel removed
(Para. 2-12).
Materials /Parts
Rubber grommet P/N 508-0117
Relay, 24 Vdc P/N 307-2613
Relay, 24 Vdc P/N 307-2612
Toggle switch P/N 308-0069
Burden resistor P/N 304-0787