TM 55-1905-223-24-17
d. Install new bushing (8) into impeller (9).
e. Install impeller onto shaft of motor (10).
f.
Connect the vane section (4) to main body of fan unit (1) with mounting hardware (2, 3).
g. Install fan (REPLACEMENT step in this procedure).
REPLACEMENT
a. Install fan unit (1) to companion flanges (7) on ducting with mounting hardware (5, 6, 11, 12).
b. Connect electrical wiring to fan.
c.
Operational checks:
(1)
Turn electrical power ON.
(2)
Start and run fan to check operation.
(3)
Remove "Out of Service" tag from circuit.
3-39
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |