TM 55-1730-228-13&P
3-25. HORN-REPLACE (Continued)
3-25
Figure 3-24. Horn Replacement (Sheet 2 of 2).
(3) Remove two bolts (6) and two flat washers (7).
(4) Remove horn (3) from junction box (8).
b. INSTALLATION:
(1) Position horn (3) on side of junction box (8).
(2) Install two flat washers (7) and two bolts (6).
(3) Install two lock washers (5) and two nuts (4). Tighten nuts (4).
(4) Connect two wires (1) to horn (3) with two screws (2). Use tags for identification.
(5) Coat wire connections with silicone sealer.
(6) Connect battery ground cable. Refer to para 3-17.
(7) Perform operational check for proper function.
END OF TASK
3-62
|