TM 55-1730-228-13&P
3-22. LIMIT SWITCHES/ TOGGLE SWITCHES-REPLACE (Continued)
3-22
Figure 3-21. Toggle Switch Replacement (Sheet 2 of 2).
(2) Installation:
NOTE
Switch can only be installed one way.
(a) Place the switch (7) in same position in switch panel (2).
(b) Install washer (9) and nut (8) on the face of panel (2).
(c) Connect wires (5) to same positions as marked on switch (7) and secure with screws (6). Use tags
for terminal identification.
(d) Position switch panel (2) and gasket (4) on control console (3).
(e) Install eight screws (1) securing switch panel (2) to control console (3).
(f) Connect ground cable to battery. Refer to para 3-17.
(g) Perform operational check for proper function.
END OF TASK