CHAPTER 4
OPERATING PROCEDURES
Section I. DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS
4-1.
General. This chapter telIs what each control and indicator on the TSTS does. This
chapter also telIs how to inspect, start up, and shut down the TSTS under normal operating
conditions.
4-2. TSTC-Power Control.
TEST SET POWER switch (I)
Puts TSTC in operation and starts TSTC
a.
automatic self test.
b.
TEST SET POWER Iamp (2)
Shows TSTC is operating.
When pressed, sends electrical power to unit
UUT POWER switch/lamp (3)
c.
under test.
THERMAL MODE switch (4)
Chooses off, standby, or on mode of operation.
d.
Provides protection in case of 115 V, 60 Hz
CB1 circuit breaker (5)
e.
power overloud.
Provides protection in case of +28 V power
CB2 circuit breaker (6)
f.
overload.