Click here to make tpub.com your Home Page

Page Title: Table 3-11. Voltage Chart No. 9 - Meter Operation
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-4910-736-14&P
Voltage Chart No. 9 - Meter Operation
NOTE
All dc voltages are measured between point specified and pin E22
(instrument ground) with DC VTVM.  Battery voltage is assumed to
be 12 V.  All voltages are 20%.
FUNCTION switch position:
OHM
OHMMETER RANGE:
0-100  K
Test leads:
Shorted
Test
Step
Action:
Action:
Normal
voltage abnormal
no.
voltage normal
voltage
point
Proceed to step 2.
Refer to table 3-4.
1
Set ZERO
Lug 9 of
ADJ .
switch S3,
control
for 0.6 V
range
indication
a. (Voltage is very low:  meter
Proceed to step 3.
0.21 V
2
Pin E5
shorted, replace CR22 or
CR23 .
b. Voltage high:  proceed to
step 3.
a. Voltage is 0 V:  examine
If meter is still
0.11 v
Pin E7
3
leads from pin E5 and E7
not reading, re-
leading to meter. If in
place it.
order, replace meter.
b. Voltage high:  proceed
to step 4.
4
Examine switch S1. If
a. Replace R96.
Switch S1,
defect not apparent, check
b. Replace
section
wiring.
meter.
1R, lug 8