DISASSEMBLY OF THE TURBO INTO COMPONENT PARTS - CONTINUED
-
0008 00
10. Removal of Preformed Packings, Filter Retaining Strap, and Filter From Dust Detector Cover.
NOTE
This procedure applies to "clean air" turbo only.
a. Remove filter retaining strap (1) and filter (2).
b. Remove and discard three preformed packings (3) from underside of dust detector cover.
3
1
2
03i472m
11. Removal of Compressor Cover Inlet and Outlet Adapters and Preformed Packings.
NOTE
This procedure applies to "clean air" turbo only.
a. Remove compressor cover inlet adapter (1) and outlet adapter (2).
b. Remove and discard two preformed packings (3).
3
1
2
03i473m
END OF WORK PACKAGE