1. CLEANING. (cont.)
NOTE
Maintain  rigid  cleaning  standards.
Keep hands free of grease or oil which
would transfer dust and grit to cleaned
parts.
a. Using tape, seal oil inlet port (1) and oil discharge
port (2).
WARNING
Dry cleaning solvent P-D-680 is toxic
and  flammable.
Wear  protective
goggles and gloves and use only in a
well ventilated area.  Avoid contact
with skin, eyes, and clothing and don't
breathe vapors. Do not use near open
flame or excessive heat.  The flash
point is 100 138F (38-C 50C). If
F
-
-
you  become  dizzy  while  using
cleaning  solvent,  get  fresh  air
immediately and get medical aid.  If
contact with eyes is made, wash your
eyes with water and get medical aid
immediately.
CAUTION
Do not immerse main body of generator or the oil
pump in solvent.
Do not use high pressure steam for cleaning.
Never use caustic solution, wire brush, or steel blade
scraper on exterior surface of generator.
b. Clean main body of generator and exterior of
pump assembly with a clean rag moistened in
cleaning solvent. Do not allow solvent to touch
seals,
wired
terminals,
or
insulation.
TA315006
3-2