TM 55-4920-433-13&P
b. Connecting power to ECU.
1. Inspect installation of ECU (1) and power
cable (2).
2. Position ECU MODE SELECTOR switch
(3) to OFF.
3. Remove cap (4) from receptacle (6).
4. Push end of connector (5) into power
input receptacle (6). Push until seated.
5. Screw
connector
lock
ring
(7)
on
receptacle (6).
6. Repeat steps 1 thru 5 with other ECU.
c. Disconnecting power distribution to panel to
1. Ensure all circuit breakers on the power
distribution panel are in the off position.
2. Ensure pigtail is connected to the power
distribution panel.
3. A qualified electrician will connect black
wire from pigtail to lug L1 on generator, red wire to L2,
green wire to L3, and white wire to LO.
Change 1 2-17