BRAKE FAILS TO HOLD TEST STAND IN SET POSITION.
Up
TM-55-4920-426-13-P Gasoline Engine Driven Hydraulic Systems Test Stand Type Type D5-D P/N 79009-100 NSN
Next
TROUBLESHOOTING CHART - Continued - TM-55-4920-426-13-P0075
TM 55-4920-426-13&P
Section IV. TROUBLESHOOTING - Continued
TROUBLESHOOTING CHART - Continued
3-8
3-8
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM D5-D HYDRAULIC TEST STAND
1. ENGINE FAILS TO TURN OVER.
Step 1.
Inspect battery for serviceability and proper connections.
Secure cables to battery post, and service batteries (Para. 3-51).
Step 2.
Inspect starter cable for connection
Secure.
Inspect starter circuit for continuity.
Step 3.
Test.
Inspect starter brushes for wear.
Step 4.
Replace (brushes) (Para. 4-18, AVIM).