Page Title: Air Start Main Generator (STBD).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-1915-200-10
lubber line, and the relative heading change, (inner)
scale, indicates zero.
NOTE
2-5.5. Air Start Main Generator (STBD).
If the ship service diesel generator
requires extra cooling, the suction
a. On main switchboard (FIGURE 2102, Sheet 1 of
and discharge valves (5 and 16) to
7), set MAN/OFF/AUTO switch (19) to the AUTO
the cooling coils located in ballasts
position.
tanks may be opened.
b. Align fuel oil service piping system to STBD
ship's service diesel generator (FIGURE 2-121) as
d. On port side of air start generator, twist the kill
follows:
pushbutton (6, FIGURE 2-122) clockwise to ensure it is
(1) Open STBD generator's fuel oil supply
in the run position.
valve (6).
e. Open generator air cutout valve (34, FIGURE 2-
(2) Open STBD generator's fuel oil filter inlet
124).
valve (7).
f. Open valves (14, 17 and 34, FIGURE 2-108,
Sheet 1 of 4).
NOTE
g. On Engine Room Console (FIGURE 2-106,
Place one fuel oil filter in operation
Sheet 5 of 12), press SGE start pushbutton (43).
and keep second as backup.
NOTE
(3) Open fuel oil filter outlet valve (9).
If engine fails to start within 30
seconds,
release
the
starter
(4) Open return fuel oil discharge valve (1).
pushbutton. Wait 2 minutes to allow
(5) Flood the starboard generator fuel system
the starter motor to cool before
by pumping with the hand operated priming pump (13)
using it again.
until a slight pressure is indicated on the engine fuel
pressure gauge (4, FIGURE 2-122).
h. Allow engine to run 3 to 5 minutes or until water
c. Align STBD ship service diesel generator
temperature (9, Sheet 2 of 12) begins to rise.
cooling water piping system (FIGURE 2-123) to air start
generator as follows:
CAUTION
(1) Open STBD generator cooling water
suction valve (6) from keel cooler.
If the oil pressure does not rise to 45
psi within 15 seconds, STOP the
(2) Open STBD expansion tank discharge
engine and refer the generator to unit
valve (12).
maintenance.
(3) Open STBD generator cooling water
discharge
valve
(15)
to
keel
cooler.
i. On main switchboard FIGURE 2-102, Sheet 1 of
7, set selector switch (8) to Gen. No. 2.
j. Increase GEN 2 SPEED CONTROL (20) on
main switchboard until Hertz meter (7) reads 60.2.