TM 55-1905-223-24-4
FIGURE 4-90. Removing Minor Grooves/Correcting Minor Out of Taper.
CAUTION
Be extremely careful not to hone the bore out of specification. Inspect at 10 second intervals.
(4)
Immediately clean the cylinder bores with a strong solution of laundry detergent and hot water.
(5)
Check the bore cleanliness by wiping with a white, lint free, lightly oiled cloth. If grit residue is sill present, re-
t
clean.
WARNING
High pressure compressed air tanks, piping systems, and air operated
equipment has a potential for serious injury to eyes and exposed areas of skin
due to escaping air pressure.
f.
Wash the cylinder block with solvent. Dry the block using compressed air.
4-63