Click here to make tpub.com your Home Page

Page Title: REPLACEMENT
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-1905-223-24-17
f. Remove the mounting hardware from each steel leg (4) and remove the condenser (1).
REPLACEMENT
a. Remove temporary pipe coverings (rags) and clean the connection portion of pipes of dirt or grease.
Remove any solder build-up on connections by heating with soldering torch and wiping with clean rag.
CAUTION
Do not allow solder particles or other debris to enter piping or
condenser.
b. Align all piping connections, position condenser (1), and install mounting hardware for each steel leg (4).
c. Connect (solder) the following lines to the condenser (1):
(1) Refrigerant outlet line connection (6).
(2) Seawater inlet line connection (5).
(3) Seawater outlet line connection (3).
(4) Refrigerant inlet line connection (2).
d. Open external seawater inlet and outlet valves.
e. Charge system with R-22 refrigerant.
f. Operational check:
(1) Turn electrical power ON.
(2) Start and run air conditioner to check operation.
(3) Remove "Out-of-Service" tag from circuit.
2-107